The protocol version checking on the grid server connector seemed to have a bug. I think I fixed it.
parent
a31e5e799e
commit
f7d8952946
|
@ -159,7 +159,24 @@ namespace OpenSim.Server.Handlers.Grid
|
|||
m_log.WarnFormat("[GRID HANDLER]: no maximum protocol version in request to register region");
|
||||
|
||||
// Check the protocol version
|
||||
if ((versionNumberMin > ProtocolVersions.ServerProtocolVersionMax && versionNumberMax < ProtocolVersions.ServerProtocolVersionMax))
|
||||
// This is how it works:
|
||||
// Example 1:
|
||||
// Client: [0 0]
|
||||
// Server: [1 1]
|
||||
// ==> fail
|
||||
// Example 2:
|
||||
// Client: [1 1]
|
||||
// Server: [0 0]
|
||||
// ==> fail
|
||||
// Example 3:
|
||||
// Client: [0 1]
|
||||
// Server: [1 1]
|
||||
// ==> success
|
||||
// Example 4:
|
||||
// Client: [1 1]
|
||||
// Server: [0 1]
|
||||
// ==> success
|
||||
if ((versionNumberMin > ProtocolVersions.ServerProtocolVersionMax || versionNumberMax < ProtocolVersions.ServerProtocolVersionMin))
|
||||
{
|
||||
// Can't do, there is no overlap in the acceptable ranges
|
||||
return FailureResult();
|
||||
|
|