When this setting is false and other defaults haven't been changed, scripts entering the simulator from another sim are automatically restarted but their state is not preserved.
When this setting is true, state that accompanies the script is reloaded (e.g. if a script had a variable i = 1 when leaving the source region, it will still have i = 1 on the destination region).
This setting does not affect crossings when regions are run in the same simulator. In this case, state is already preserved.
Some items had completely wrong permissions - this is easier than correcting them all.
The ability to set permissions in xml is retained since there are use cases for this (e.g. to create no-mod library scripts)
Library items always need the same permissions, so it doesn't make sense to load them from the xml files. This just opens the door to permissions mistakes.
This matches the ability to disable the memory part
This is controlled through the FileCacheEnabled parameter in FlotsamCache.ini
Default is true, so existing installations are not affected.
Improved fcache command feedback when various caches are disabled.
Re-enabled test for flotsam cache with file caching disabled.
Instead of performing the 4096 check when the region is linked (and subsequently removing the link), leave the link in place and perform the check in the entity transfer module
This allows us to explicitly tell the hypergridder why the teleport failed (region out of range).
It also allows people on regions that are within range (on a large source grid) to teleport.
The Check4096 config parameter in the [GridService] section is replaced by a max_distance paramter in a new [EntityTransfer] section in OpenSimDefaults.ini
Since the parameter is in OpenSimDefaults.ini no action needs to be taken unless you want to increase this limit. It could also be decreased.
The check is being made in the base entity transfer module, since I believe the viewer problem occurs both on extremely large grids and while hypergridding.
Changed the experimental capability introduced a couple of commits ago: now sending that extra information as part of the response in the SimulatorFeatures cap.
For the most part, defaults are made to match those already in FlotsamCache.ini.example.
The one exception is that the 48 hour file timeout from the code is used instead of the 0 hours that was in the example file. This can be tweaked if necessary.
Most importantly, the default cache directory is now ./assetcache (as in FlotsamCache.ini.example) rather than ./FlotsamAssetCache (as was the internal code default).
Therefore, if you were using flotasm without using the config file, then please rename your cache directory or start using the ini file and change the default there if you want to keep using your existing cache.