The packet was actually being handled but not acted on.
This change extends the default timeout for paused clients to 5 minutes
and makes both the paused and non-paused timeout periods configurable.
If active, the physics module can return arbitrary stat counters that can be seen via the MonitoringModule
(http://opensimulator.org/wiki/Monitoring_Module)
This is only active in OdeScene if collect_stats = true in [ODEPhysicsSettings].
This patch allows OdeScene to collect elapsed time information for calls to the ODE native collision methods to assess what proportion of time this takes compared to total physics processing.
This data is returned as ODENativeCollisionFrameMS in the monitoring module, updated every 3 seconds.
The performance effect of collecting stats is probably extremely minor, dwarfed by the rest of the physics code.
Without this, LL 3.3.1 continually pushes LLInventoryModelFetchDescendentsResponder::error 499 to its log.
This cap will be ignored by older viewers - UDP inventory will work normally.
If velocity reaches 256 in any vector then bad things happen with ODE, so we now clamp this value.
In addition, a falling avatar is clamped by default at 54 m/s, which is the same as a falling skydiver.
This also appears to be the value used on the linden lab grid.
This should resolve http://opensimulator.org/mantis/view.php?id=5882
Naturally, default is true.
When set to false, "phantom" flags on prims can be set as usual but all prims remain phantom.
This setting is for test purposes.
This switch does not affect the collision of avatars with the terrain.
Enabling this by setting Cap_FetchInventoryDescendents2 = "localhost" in the [ClientStack.LindenCaps] section of OpenSim.ini downloads inventory via http rather than udp in later viewers.
From field experience, we know that simulators can be unstable if a user logs in before the scripts have finished loading.
This commit turns login_disable = true in [RegionReady] on by default which prevents this from happening.
If you want the old behaviour, please copy these section from OpenSimDefaults.ini into OpenSim.ini and set login_disable = false
This is to allow broader subsitution in the future. Currently, the only substitions are \R (for region name) and \\ (for a single backslash)
e.g. "Region (\R) " is the current and continuing default prompt
This renames custom_prompt in [Startup] to ConsolePrompt
PARCEL_GROUP, PARCEL_OWNER, ESTATE_MANAGER and REGION_OWNER can be combined with the existing agent uuid option to limit ossl functions to agents and owner classes.
Signed-off-by: BlueWall <jamesh@bluewallgroup.com>
As discussed in http://lists.berlios.de/pipermail/opensim-dev/2011-October/010599.html and the preceeding thread mails,
the aim of this setting is to avoid overloading the viewer UDP connection where the client is failing to ack packets.
Please mantis any anomalous viewer connection behaviour which wasn't there before.
This had stopped working. However, at the moment it still allows the physics flag to be set even though this has no effect. This needs to be fixed.
Default for this flag is true as previously.
This exactly fits five ODE steps in the default frame time (0.089).
This means that ODE execution time now matches the default minimum frame time.
This eliminates errors between distance travelled as calculated by ODE in clear air and simple extrapolation.
On the old values, ODE would actually do calculations over 0.1 seconds rather than 0.089.
This means that once the avatar is at top speed, no additional packets need to be sent for smooth movement, since no error develops between server and viewer.
This approach replaces the tweaks previously discussed on the opensim-dev mailing list
Settings are at bottom of [Startup] in OpenSimDefaults.ini, override in OpenSim.ini to change
Defaults are the same as previously.
More information to come on opensim-dev shortly.
Feel free to tweak but if you do please don't expect any support unless feedback on certain tweaks is explicitly requested.
Also adds password check to some functions where this was missing and fixes some parameter checking.
This is a patch from http://opensimulator.org/mantis/view.php?id=5715 with a few small unrelated spacing tweaks from me.
Thanks Michelle Argus.
I added the boolean config setting "allow_regionless", defaulting to false. If set to true, opensim will start up ok if no region configurations are found in the specified region_info_source. It will not ask the user to create a region.
When this setting is false and other defaults haven't been changed, scripts entering the simulator from another sim are automatically restarted but their state is not preserved.
When this setting is true, state that accompanies the script is reloaded (e.g. if a script had a variable i = 1 when leaving the source region, it will still have i = 1 on the destination region).
This setting does not affect crossings when regions are run in the same simulator. In this case, state is already preserved.