This is to address an issue where HTTP script functions could make calls to localhost and other endpoints inside the simulator's LAN.
By default, calls to all private addresses are now blocked as per http://en.wikipedia.org/wiki/Reserved_IP_addresses
If you require exceptions to this, configure [Network] OutboundDisallowForUserScriptsExcept in OpenSim.ini
closer to SL. This change should address small floor edges acting like
walls, approaching a step at any angle (other than walking backwards)
will allow walking up, and reducing the avatar pop-up when going up
stairs.
Note that I also made things consistent by removing both the EstateDataService and the SimulationService into their own dlls, just like all other services. They really didn't belong in Services.Connectors, since everything in that component is about network connectors to robust backends. We may have too many dlls, and at some point it might not be a bad idea to merge all services into one single dll, since they all have more or less the same dependencies.
This cleans up Opensim's use of mono addins. In particular, the extension points /OpenSim/RegionModules and /OpenSim/WindModule moved from OpenSim.exe to OpenSim.Region.Framework.dll. From here on, developers of region modules should declare their dlls to be dependent on OpenSim.Region.Framework, starting with version 0.8.1
Additional changes:
- Addins version uniformly updated to 0.8.1. These numbers should be compatible with the release numbers or else it becomes very confusing.
- Mono addins directives moved from files addins.xml to embedded directives in the class and assembly declarations, to make it all consistent
throttles. Setting adaptive_throttle_min_bps will change the
minimum rate that the adapative throttles will drop to in case
of network packet loss. The current rate default rate is 256kbps.
The viewer can throttle rates under that amount, but the dynamic
adaptation will not.
If log level is 1 then every script load is logged.
This means the <logger name="OpenSim.Region.ScriptEngine.XEngine"> section in OpenSim.exe.config is no longer needed to avoid log spam on regions with many scripts and can be removed.
This is implemented with a new collision type (PhantomToOthersAvatar) to potentially allow colliding and non-colliding avatars to be present in the same scene.
So there is no provision yet for giving avatars different collision types.
This commit replaces the temporary change in commit f3eaa6d8 where avatars would never collide when using BulletSim
This is equivalent to the av_av_collisions_off option in ODE.
This resolves an issue with pCampbot where some bots would occasionally connect with the same UDP source port.
This sometimes led to console messages where bots would report receiving packets multiple times that weren't marked as resends.
DLLs built under windows
This shows summary wearables information (shape, hair, etc.) for all avatars in the scene or specific information about a given avatar's wearables.
Similar to the existing "attachments show" command.
This is the same as already done for scene_throttle_max_bps
Internally, the token buckets are in bytes and the other help text makes it clear that the number is bytes per second
(though with the wrong assumption that 1 mbit = 1024 * 1024 bits whereas 1 mbit = 1000 kbits = 1000000 bits)
This resolves an issue with pCampbot where some bots would occasionally connect with the same UDP source port.
This sometimes led to console messages where bots would report receiving packets multiple times that weren't marked as resends.
DLLs built under windows
This setting was originally added some time ago to deal with issues where appearance was not received properly by all users.
However, it does not scale well with large numbers of agents.
Disabling to see if the original problem has abated or whether this will have to be tackled in another way.