People using standalone in master, please update your StandaloneCommon.ini according to this change.
People using robust in master, please update your Robust.HG.ini.example[.HG].ini according to this change.
It would certainly be nice to change the default script on disk, but this is currently unused and isn't a suitable default.
At this location it would also stop an easy manual deletion of script engine compiles and state.
This is configured in the new [Estates] section of OpenSim.ini.
If a default estate is configured then all new regions are automatically joined to it instead of asking the user.
If the default estate does not already exist then it is created.
Current default behaviour remains the same - the user is asked for estate details when necessary.
Thanks to Frenando Oliveira for the patch which I adapated further.
In this zip, it's called System.Data.SQLite.dll. We rename it to lib64/sqlite3.dll
This is a little unexpected but it works. For some reason my hand-rolled one in Visual Studio 2008 did not.
This is sqlite 3.7.10. Other libraries are still currently 3.7.6 but this should make no difference.
This should make it possible to use OpenSim.exe on 64-bit Windows now, though currently the bullet physics plugin will still complain (can be ignored if you are not using bullet).
In over 4 years this never progressed beyond an unimplemented stub.
This doesn't mean that it can't come back if someone is interested in implementing PhysX support.
In theory, this means that a 64-bit Windows OS user can now run OpenSim.exe with ODE and use more than 2 (or 3) GB of memory.
However, this is completely untested since I don't currently own a 64-bit Windows box. Feedback appreciated.
Using OpenSim.32BitLaunch.exe should continue to work. Other platforms are unaffected.
This will currently not work with sqlite - I will add that too if this works.
If velocity reaches 256 in any vector then bad things happen with ODE, so we now clamp this value.
In addition, a falling avatar is clamped by default at 54 m/s, which is the same as a falling skydiver.
This also appears to be the value used on the linden lab grid.
This should resolve http://opensimulator.org/mantis/view.php?id=5882
These can be run using the "nant torture" target. They are not part of "nant test" due to their long-run future nature.
Such tests are designed to do some testing of extreme situations and give some feedback on memory usage, etc.
However, data can be inconsistent due to different machine circumstances and virtual machine actions.
This area is under development.
This reverts commit 4eef6725f4.
Reverting for now since this fails with "terminate called after throwing an instance of 'std::bad_alloc'" on Wright Plaza instances.
The osGetGrid**** functions will now get the grid settings from the GridInfoService. Set the GridInfoURI in your ./bin/config-include/GridCommon.ini [GridInfo] section.
As discussed on the opensim-dev mailing list, this is to avoid a demonstrated ODE collider segfault when stress-testing a simulator running more than one region using the bundled pCampbot.exe
As before, the ODE revision used is r1755 - only the collider has changed.
Tests so far reveal little performance change.
However, if noticeable issues do arise, please report on mantis and/or the opensim-dev mailing list.
The previous libraries are temporarily in bin/Physics-previous-ode-libs
These can be copied back to bin if one wants to compare behaviour with the previous libraries.
Add configuration option - DEBUG to enable debugging methods. This is temporary for helping users testing teleport routing be able to report back the data with the test cases. We can remove when finished with this, or leave it if it proves to be useful.
Users: set DEBUG = true in OpenSim.ini to get more information from teleport routing. The default is false. It presently prints the TeleportFlags value.
Naturally, default is true.
When set to false, "phantom" flags on prims can be set as usual but all prims remain phantom.
This setting is for test purposes.
This switch does not affect the collision of avatars with the terrain.
Enabling this by setting Cap_FetchInventoryDescendents2 = "localhost" in the [ClientStack.LindenCaps] section of OpenSim.ini downloads inventory via http rather than udp in later viewers.
This will hopefully address mantis 5471, 5694 and 5718.
This code is now in opensim-libs, along with Diva's slightly older patches (which were already applied to the DLLs in the opensim tree).
Thanks Oren!
From field experience, we know that simulators can be unstable if a user logs in before the scripts have finished loading.
This commit turns login_disable = true in [RegionReady] on by default which prevents this from happening.
If you want the old behaviour, please copy these section from OpenSimDefaults.ini into OpenSim.ini and set login_disable = false
This is to allow broader subsitution in the future. Currently, the only substitions are \R (for region name) and \\ (for a single backslash)
e.g. "Region (\R) " is the current and continuing default prompt
This renames custom_prompt in [Startup] to ConsolePrompt
PARCEL_GROUP, PARCEL_OWNER, ESTATE_MANAGER and REGION_OWNER can be combined with the existing agent uuid option to limit ossl functions to agents and owner classes.
Signed-off-by: BlueWall <jamesh@bluewallgroup.com>
These are disabled by default, as before. Please only turn these on in secure grids, since they allow the same facilities as the existing SetPassword call (also disabled by default)
These facilities can be helpful when integrating external systems, in addition to the existing option of adapting an IAuthenticationService or using WebLoginKey
This is to make it easier to change all these names at once, where all grids services are running from the same location.
Also rearranges some lines in [Modules] so that StandaloneCommon.ini.example and GridCommon.ini.exmaple are consistent.
This is switched on by setting AllowSetPassword = true in the [AuthenticationService] section of Robust.ini or Robust.HG.ini
Default is false as before.
Default is false, as before.
Enabling AllowCreateUser in [UserAccountService] for ROBUST allows avatars to be created via an http call, with viewer 2 appropriate bits and pieces.
Only Ruths can be created at present.
Please don't rely on the config since at some point CreateUser will be moved to a separate co-ordinating service.
As discussed in http://lists.berlios.de/pipermail/opensim-dev/2011-October/010599.html and the preceeding thread mails,
the aim of this setting is to avoid overloading the viewer UDP connection where the client is failing to ack packets.
Please mantis any anomalous viewer connection behaviour which wasn't there before.
This had stopped working. However, at the moment it still allows the physics flag to be set even though this has no effect. This needs to be fixed.
Default for this flag is true as previously.
This exactly fits five ODE steps in the default frame time (0.089).
This means that ODE execution time now matches the default minimum frame time.
This eliminates errors between distance travelled as calculated by ODE in clear air and simple extrapolation.
On the old values, ODE would actually do calculations over 0.1 seconds rather than 0.089.
This means that once the avatar is at top speed, no additional packets need to be sent for smooth movement, since no error develops between server and viewer.
This approach replaces the tweaks previously discussed on the opensim-dev mailing list
Settings are at bottom of [Startup] in OpenSimDefaults.ini, override in OpenSim.ini to change
Defaults are the same as previously.
More information to come on opensim-dev shortly.
Feel free to tweak but if you do please don't expect any support unless feedback on certain tweaks is explicitly requested.
Also adds password check to some functions where this was missing and fixes some parameter checking.
This is a patch from http://opensimulator.org/mantis/view.php?id=5715 with a few small unrelated spacing tweaks from me.
Thanks Michelle Argus.